Introduction
AFDD/AFCI Arc fault protectorIt is assembled by a miniature circuit breaker and an arc fault protection module, and has protection functions such as overload, short circuit, and arc fault protection.
AFDDArc fault protectorSuitable for communication 50Hz, rated voltage 230V, rated current to 63AIn the following lines, it is used to protect the overcurrent of the lines of buildings and similar purposes, and at the same time, it can detect many fire risks caused by the rupture of electrical devices or the aging of wires in advance, and protect against grounding arc faults, parallel arc faults and series arc faults. To a certain extent, the occurrence of fire safety accidents has been reduced, and the safety of people’s lives and property has been effectively protected.
Second, product features
a)Overload and long delay protection;
b)Overload and short-delay protection;
c)Instantaneous trip protection;
d)Series arc fault protection;
e)Parallel arc fault protection;
FGround arc fault protection;
g)Multiple current specifications.
Normal working conditions and installation conditions
aAmbient air temperature
The ambient air temperature is not higher+70℃,Not less than-35℃,24The average of the hours does not exceed+35℃;
Note: The ambient air temperature is higher+70℃or below-35℃conditions of use AFDD Arc fault protection is off The roader should be negotiated with the manufacturer;
bAltitude
The altitude of the installation site does not exceed 2000m;
cAtmospheric conditions
The relative humidity of the atmosphere is at its highest temperature in the surroundings+60℃time not exceeded 50%, which can have a higher phase at lower temperatures to humidity, eg 20℃time 90%, for occasional condensation due to temperature changes, protective measures should be taken;
dInstallation conditions
Arc fault protectorThe external magnetic field near the installation site should not exceed the geomagnetic field in any direction5Fold; The installation position should be vertical, and the inclination in all directions should not exceed 10°; Installed in a place where there is no shock vibration and no rain or snow Square; Adopt standards TH35-7.5 section steel installation rail installation;
ePollution Level:2 level
fInstallation Category:ⅢKind;
gIngress Protection:IP20(Installed in a distribution box, distribution cabinet or box.) IP40);
hWith it N When wiring, the neutral wire must be connected to the mark N Identification of the poles.
Fourth, the size of the product