Тема XStore Темы WordPress для электронной коммерции XStore Темы WordPress WooCommerce Премиальные темы WordPress Темы для WooCommerce Форум поддержки wordpress Лучшие темы для WooCommerce XStore Темы WordPress Документация XStore Темы WordPress для электронной коммерции

Цифровой многофункциональный измеритель мощности, тип 96, тип 72

JGD multi-functional power meter is designed for the power monitoring needs of power systems, industrial and mining enterprises, public facilities, and intelligent buildings. It can measure all common power parameters, such as three-phase current, voltage, active and reactive power, electricity, harmonics, etc. Because the power meter also has a complete communication networking function, we call it a network power meter. It is ideal for real-time power monitoring systems. The meter has a high performance-to-price ratio and can directly replace conventional power transmitters and measuring instruments. As an advanced intelligent and digital front-end acquisition element, this series of network instruments has been widely used in various control systems, SCADA systems and energy management systems

JGDMulti-function power meterIt is designed for the power monitoring needs of power systems, industrial and mining enterprises, public facilities, and intelligent buildings. It can measure all common power parameters, such as three-phase current, voltage, active and reactive power, electricity, harmonics, etc. Because the power meter also has a complete communication networking function, we call it a network power meter. It is ideal for real-time power monitoring systems.

The meter has a high performance-to-price ratio and can directly replace conventional power transmitters and measuring instruments. As an advanced intelligent and digital front-end acquisition element, this series of network instruments has been widely used in various control systems, SCADA systems and energy management systems.

Product standards

GB/T 22264.1-2008 Mounted digital display electrical measuring instruments – Part 1: Definitions and general requirements

GB/T 22264.7-2008 Mounted digital display electrical measuring instruments – Part 7: Special requirements for multifunctional instruments

GB/T 22264.8-2008 Mounted digital display electrical measuring instruments – Part 8: Recommended verification methods

GB/T 17215.322-2008 Alternating current measuring equipment—Special requirements—Part 22: Static active energy meters (0.2S and 0.5S)

GB/T 17215.323-2008 Alternating current measuring equipment—Special requirements—Part 23: Stationary reactive energy meters (Class 2 and 3)

DL/T 614-2007 Multifunctional energy meter

GB14287-2005 Electrical fire monitoring system

GB50045-95 Code for fire protection design of high-rise civil buildings

GB50054-95 Design Code for Low-Voltage Power Distribution

GB50096 Residential Design Codes

GB13955-2005 Installation and operation of residual current action protection device

GB50016-2006 Code for Fire Protection Design of Buildings

Model nomenclature

 

Performance characteristics:

High-precision measurement of three-phase voltage, three-phase current, active power, reactive power, apparent power, power factor, frequency and other electrical parameters

Forward and reverse active/reactive energy metering

Time-of-use electric energy metering, time-of-use electric energy timing meter reading

Measure the total harmonic distortion rate (THD) of three-phase voltage and three-phase current, and the odd harmonic component from 2 to 31

Provide digital tube or LCD display, local data query

The menus are intuitive and the keys are easy to use

The current and voltage conversion ratio are programmable

Provides multi-loop leakage current monitoring

Provide multi-loop control node, which can be used for alarm, trip and other control

Support fire-fighting linkage and remotely cut off the fault loop

Support RS-485 communication, Modbus-RTU protocol

It supports switching input, switching output, analog transmission output, and power pulse output

It is easy to install, simple to wiring, and small in engineering

Wide-range AC/DC universal power supply: AC/DC 80V~270V

It can complete the networking of a variety of communication software in SCADA and PLC

Technical Indicators

Measurement accuracy

Voltage 0.5 class

Current 0.5 class

Active power 0.5 class

Reactive power 0.5 class

Power factor 0.5 level

Frequency ±0.02Hz

Active energy 0.5S or 0.2S

Reactive energy level 1 or 2

Signal input

Wiring method: three-phase four-wire, three-phase three-wire

Rated voltage: AC 57.7V, AC 100V, AC 220V, AC 380V

Rated current: AC 1A, AC 5A

Overload Voltage: 1.2 times (continuous), 2 times/1 sec (instantaneous)

Current: 1.2x (continuous), 10x/5 sec (instantaneous)

Power consumption Voltage: <1VA/phase, Current: <0.4VA/phase

Impedance Voltage: >300kΩ, Current: <20mΩ

Frequency: 45~65Hz

Auxiliary power supply

Working range AC/DC: 80V~270V

Power consumption <4VA

Functional modules

Communication interface: Support 1 channel RS-485 communication, Modbus-RTU protocol

Baud rate: 1200~9600bps, default 2400 bps

Switching inputs support 4 dry junction inputs

Switching output Support 3 relay outputs, capacity: AC 250V/5A, DC 30V/5A

Transducer output Support 1 analog output: 0/4~20mA or 0~5/10V

Power pulse output Support 2 power pulse output, constant: 8000imp/KWh(Kvarh)

environment

Operating temperature: -10°C~+55°C

Storage temperature: -25°C~+70°C

Relative humidity ≤93%, no corrosive gas location

≤ 2500m above sea level

safe

Insulation resistance >100MΩ

AC withstand voltage AC 2KV

Electromagnetic compatibility performance

Electrostatic discharge level 4

Electrical fast transient burst class 4

Surge (Shock) Level 4

Dimensions

Frame size(mm) 120×120;96×96; 80×80;72×72

Cut-out size(mm) 111×111;92×92; 76×76;68×68